中卫市LGJ95/20钢芯铝绞线多少钱一公斤:推荐
中卫市LGJ95/20钢芯铝绞线多少钱一公斤:推荐见下表钢芯铝绞线技术参数表一型号参数钢芯铝绞LGJ-10/2钢芯铝绞LGJ-16/3钢芯铝绞LGJ-25/4钢芯铝绞LGJ-35/6钢芯铝绞LGJ-50/8钢芯铝绞LGJ-50/30钢芯铝绞LGJ-70/10钢芯铝绞LGJ-70/40结构根数/直径n/mm)铝6/1.506/1.856/2.326/2.726/3.2012/2.327/3.8012/2.72钢1/1.501/1.851/2.321/2.721/3.207/2.321/3.807/2.72计算截面积mm2铝10.6016.1325.3634.8648.2550.7368.0569.73钢1.772.694.235.818.0129.5911.3440.67总计12.3718.8229.5940.6756.2980.3279.39110.40导体外径(mm)铝4.505.556.968.169.6011.6011.4013.60钢1.501.852.322.723.206.963.808.16计算重量(kg/km)铝29.244.369.795.8132.5140.6187.0193.3钢13.720.932.945.262.6231.488.2318总计42.965.2102.6141.0195.1372.0275.2511.320℃直流电阻(Ω/km)2.7061.7791.1310.82800.59460.56920.42170.4141计算拉断力(N)4120613092901263016870426202339058300终弹性系数(N/mm2)790007900079000790007900010500079000105000线系数(1/℃)19.110-619.110-619.110-619.110-619.110-618.510-619.110-618.310-6圆铝线绞后抗拉强度不小于N/mm2)183176168160157168152160镀锌(锌铝合金镀层)钢绞线绞后抗拉强度不小于(N/mm2)12441244124412441244124412441244钢丝镀层重量不小于(g/m2)183214229229244229259229绞捻方向(外层)右右右右右右右右交货长度不小于(m)30003000300030002000300020002000适用GB1179-83GB1179-83GB1179-83GB1179-83GB1179-83GB1179-83GB1179-83GB1179-83钢芯铝绞线技术参数表二型号参数钢芯铝绞LGJ-95/15钢芯铝绞线LGJ-95/20钢芯铝绞线LGJ-95/55钢芯铝绞线LGJ-120/7钢芯铝绞线LGJ-120/20钢芯铝绞线LGJ-120/25钢芯铝绞线LGJ-120/70钢芯铝绞线LGJ-150/8结构根数/直径(n/mm)铝26/2.157/4.1612/3.2018/2.9026/2.387/4.7212/3.6018/3.20钢7/1.677/1.857/3.201/2.907/1.857/2.107/3.601/3.20计算截面积mm2铝94.3995.1496.51118.89115.67122.48122.15144.76钢15.3318.8256.306.6118.8224.2571.258.04总计109.72113.96152.81125.50134.49146.73193.40152.80导体外径(mm)成品13.6113.8716.0014.5015.0715.7418.0016.00钢芯5.015.559.602.905.556.3010.803.20计算重量(kg/km)铝260.9261.8267.5327.6319.7337.4339.9398.8钢119.9147.1440.251.4147.1189.2555.762.6总计380.8408.9707.7379.0466.8526.6895.6461.420℃直流电阻(Ω/km)0.30580.030190.29920.24220.24960.23450.23640.1989计算拉断力(N)3500037200781102757041000478809837032860终弹性系数(N/mm2)760007600010500066000760007600010500066000线系数(1/℃)18.910-618.510-618.310-621.210-618.910-618.310-618.310-621.210-6圆铝线绞后抗拉强度不小于N/mm2172152157160168151154156镀锌(锌铝合金镀层)钢绞线绞后抗拉强度不小于(N/mm2)12441244124412441244124412441244钢丝镀层重量不小于(g/m2)198214244244214214259244外层绞向右右右右右右右交货长度不小于(m)20002000200020002000200020002000适用GB1179-83GB1179-83GB1179-83GB1179-83GB1179-83GB1179-83GB1179-83GB1179-83钢芯铝绞线技术参数表三型号参数钢芯铝绞线LGJ-150/20钢芯铝绞线LGJ-150/25钢芯铝绞线LGJ-150/35钢芯铝绞线LGJ-185/10钢芯铝绞线LGJ-185/25钢芯铝绞线LGJ-185/30钢芯铝绞线LGJ-185/45结构根数/直径(n/mm)铝24/2.78文章来源:https://www.jinchutou.com/p-93256181.html技术部分总则1.1.1我公司提供的产品文件提出的技术要求。每米多少公斤主导能用95钢芯铝绞线每米多少公斤对高发电的输电线路,还是由线路的路途有限,又不不能少于在一瓶路途上架多条线路,们顾及了基于一瓶路途,一盒铁塔,挂多条发展,即一项线路稍微于架了多条线路的法则;对500KV的输电线路,繁多基于挂四条发展的旅途,这一类的架线的旅途称为同塔并架。
为了避免导线划痕的发生,在生产中应从以下几个方面进行控制:
首先从导体本身来考虑:
一铝杆不受潮,铝杆受潮造成拉丝模孔工作区铝屑滞留,油不能全部进入工作区,从而拉出来的铝线不圆整、不光滑。
第二应拉丝油清洁,不含水分。由于在拉丝中,拉丝油由区进入工作区时处于高温状态,如果含有一定的水分,致使油稀释,效果大大,从而造成导线划痕及铝线断头。
其次从生产方面考虑,应注意以下问题:
拉丝工序中:
(1)检查拉丝机模具是否放置准确。
(2)检查拉丝鼓轮是否后起沟槽,以及是否有压线现象;
(3)检查拉丝模具区表面光洁度是否符合要求,以及有无铝屑堵塞现象。
绞线工序中:
(1)检查线盘转动灵敏;中卫市LGJ95/20钢芯铝绞线多少钱一公斤:推荐
(2)检查线盘张力是否均匀一致;
(3)检查单线是否的轻微压线或排线不平整现象;
(4)检查绞合时单线是否在导轮的槽内。
一套铁塔,挂多条电缆,即一款相互比较于架了多条相互的法则;对500KV的输电相互,海外那么多采取挂四条电缆的道路,一样的架线的道路被看做同塔并架。钢芯铝绞线关系毛病钢芯铝绞线含有楼板方便、无限与配线易明白、相互销赃低、建筑脂肪增长大、又利驾驶经过冰川和山谷等尤其更加的摸脸、含有充分的导电用途和足够的效果人、模板、塔杆这样状态的可伸张等所长优势不足特点。大征公司拥有先进的生产设备和精湛的技术工艺、齐全的检测设备和完善的检测手段、现代化的科学、严密的,连续多年大征电线被评为省、地市重合同信誉企业、消费者信得过单位及河北省计量合格单位;、服务诚信示范单位;行业示范企业;
相关文章 襄阳市LGJ70/10钢芯铝绞线工厂:好物速递 http://www.sg560.com/sells/c2257/sxyyxl123_159642530.html
*您的姓名:
*联系手机:
固话电话:
E-mail:
所在单位:
需求数量:
*咨询内容: